Search results for "MESH: Chromatography"
showing 3 items of 3 documents
Immunoaffinity purification and characterization of mitochondrial membrane-bound D-3-hydroxybutyrate dehydrogenase from Jaculus orientalis.
2008
Abstract Background The interconversion of two important energy metabolites, 3-hydroxybutyrate and acetoacetate (the major ketone bodies), is catalyzed by D-3-hydroxybutyrate dehydrogenase (BDH1: EC 1.1.1.30), a NAD+-dependent enzyme. The eukaryotic enzyme is bound to the mitochondrial inner membrane and harbors a unique lecithin-dependent activity. Here, we report an advanced purification method of the mammalian BDH applied to the liver enzyme from jerboa (Jaculus orientalis), a hibernating rodent adapted to extreme diet and environmental conditions. Results Purifying BDH from jerboa liver overcomes its low specific activity in mitochondria for further biochemical characterization of the e…
Decreasing dietary linoleic acid promotes long chain omega-3 fatty acid incorporation into rat retina and modifies gene expression
2011
International audience; Age-related macular degeneration (AMD) may be partially prevented by dietary habits privileging the consumption of ω3 long chain polyunsaturated fatty acids (ω3s) while lowering linoleic acid (LA) intake. The present study aimed to document whether following these epidemiological guidelines would enrich the neurosensory retina and RPE with ω3s and modulate gene expression in the neurosensory retina. Rat progenitors and pups were fed with diets containing low or high LA, and low or high ω3s. After scotopic single flash and 8-Hz-Flicker electroretinography, rat pups were euthanized at adulthood. The fatty acid profile of the neurosensory retina, RPE, liver, adipose tis…
Evaluation of seven immunochromatographic assays for the rapid detection of human rotaviruses in fecal specimens
2007
International audience; Seven commercially available immunochromatographic assays were tested for the rapid detection of group A rotaviruses in fecal samples compared to a enzyme immunoassay (Argene). Detection of rotaviruses in 80 ELISA positive frozen stool samples showed rates superior to 90% for three reagents (Rota Strip (Cypress Diagnostics), 98.8%; Rotascreen (Microgen), 95.0%; VIKIA Rota/Adeno (bioMérieux), 92.5%); from 82.5% to 88.8% for three others (Diarlex with centrifugation (Orion Diagnostica), 88.8%; Combo Rota/Adeno (All Diag), 87.5%; Rota/Adeno Combi Stick (bmd), 82.5%) and only 70.0% for Diarlex with filtration vial (Orion Diagnostica). The evaluation of the specificity, p…